DV10 Metrology System Issues and Tracking


TIP Last Update: JeffMangum - 16 September 2010

Issues Tracked

Associated JIRA Tickets

Metrology Sensor IDs

  • Tiltmeter: SN 8270
  • Linear Sensor: SN??

Metrology System Calibration Constants

Date SN Pad AN0 (arcsec) AW0 (arcsec) SA2 (arcsec) SA3 (arcsec) phi2 (deg) phi3 (deg)Sorted ascending NPAE (arcsec) Comments
16 September 2010
DV10
1
-19.0
-5.5
-0.113
-0.144
-20.5
26.3
??? (average)
Measured values.

Tiltmeter Metrology System Calibration Offsets

Date SN Pad TiltXOffset (arcsec) TiltYOffset (arcsec) Tiltmeter Blanking Time (sec) Tiltmeter Filter Time (sec) Comments
16 September 2010
8270
1
-17.2
+6.7
2.0/4.0
1.0
Start pointing tests

Linear Sensor Metrology System Calibration Offsets

Date Pad LS Offset 1A (mm) LS Offset 1B (mm) LS Offset 2A (mm) LS Offset 2B (mm) Comment
16 September 2010
1
-0.0185
+0.0267
-0.054
-0.0407
Start pointing tests

-- JeffMangum - 2010-09-16

This topic: Main > TWikiUsers > JeffMangum > VertexAntennaSystemTracking > VertexMetrologyTracking > DV10Metrology
Topic revision: 2011-01-05, JeffMangum
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding NRAO Public Wiki? Send feedback