DV06 Fast Switching Issues and Tracking


TIP Last Update: JeffMangum - 30 October 2009

Test Matrix Progress Tracking

Note: All entries assume measurements at P=0, 90, and 225. Notes regarding servo tuning during these measurements:

(todo - todo done - done )

 +
State Item Comment  
(Az,El) = (0,30) Completed 2010-04-30: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (0,45) Completed 2010-05-01: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (0,60) Completed 2010-05-01: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (60,30) Completed 2010-05-03: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (60,45) Completed 2010-05-03: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (60,60) Completed 2010-05-03: failures P0/P90/P225 = 1/0/0   +  
(Az,El) = (120,30) Completed 2010-05-05: failures P0/P90/P225 = 1/0/0   +  
(Az,El) = (120,45) Completed 2010-05-05: failures P0/P90/P225 = 1/0/0   +  
(Az,El) = (120,60) Completed 2010-05-05: failures P0/P90/P225 = 0/2/0   +  
(Az,El) = (180,30) Completed 2010-05-05: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (180,45) Completed 2010-05-06: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (180,60) Completed 2010-04-29: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (240,30) Completed 2010-04-29: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (240,45) Completed 2010-05-07: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (240,60) Completed 2010-04-30: failures P0/P90/P225 = 1/0/0   +  
(Az,El) = (300,30) Completed 2010-04-30: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (300,45) Completed 2010-04-30: failures P0/P90/P225 = 0/0/0   +  
(Az,El) = (300,60) Completed 2010-04-30: failures P0/P90/P225 = 0/0/0   
  

-- JeffMangum - 2009-10-30
Topic revision: r16 - 2010-05-07, JeffMangum
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding NRAO Public Wiki? Send feedback