Window Types

The window material is chosen from the leak rate measurement results, out gassing measurement results, and electrical characteristics as many other receiver have this type of window. Typically Emerson&Cummings Ecco foam PS102(dielectric = 1.02)is preferred; however, the supply is limited since this foam was manufactured with CFC's. Enough exits for the KFPA. The foam is covered with a water vapor barrier, typically Mylar, or Kapton. The results below are for the circular waveguide inputs and the rectangular wr42 waveguide outputs.

Circular

  • S11 results from a CST simulation for 0.7962" of PS102 with a 2 mil Mylar vapor barrier. Cirps102s11Mylar2.bmp

  • S21 results from a CST simulation for 0.7962" of PS102 with a 2 mil Mylar vapor barrier.Cirps102s21Mylar2.bmp

Rectangular WR42

Topic attachments
I Attachment Action SizeSorted ascending Date Who Comment
262ps102Mylar2s11.bmpbmp 262ps102Mylar2s11.bmp manage 1 MB 2008-05-13 - 16:09 StevenWhite  
262ps102Mylar2s21.bmpbmp 262ps102Mylar2s21.bmp manage 1 MB 2008-05-13 - 16:10 StevenWhite  
Cirps102s11Mylar2.bmpbmp Cirps102s11Mylar2.bmp manage 1 MB 2008-05-13 - 16:10 StevenWhite  
Cirps102s21Mylar2.bmpbmp Cirps102s21Mylar2.bmp manage 1 MB 2008-05-13 - 16:10 StevenWhite  