Laboratory Tests

Allan Variance
  • Allan Variance Measurements: Typically knee occurs greater than 50 seconds. Beam 7 R exhibits instability.
    beam1.jpg beam7.jpg
    Beam 1 L(red) & R (white) Beam 7 L (white) & R (red): unstable
Noise Temperature
  • Ray Dome Comparison Data: Gore Tex, Saran Wrap, Saran Wrap & Zitex (ZX G110), Saran Wrap & Gore Tex.
    • May_14_RxTemp_NCal.xlsx: This spreadsheet contains data for the four cases, which clearly shows a 3.5 degree increase with Gore Tex covering the feeds.

Topic attachments
I Attachment ActionSorted ascending Size Date Who Comment
May_14_RxTemp_NCal.xlsxxlsx May_14_RxTemp_NCal.xlsx manage 56 K 2010-05-19 - 08:20 StevenWhite  
beam1.jpgjpg beam1.jpg manage 58 K 2010-05-19 - 08:10 StevenWhite  
beam7.jpgjpg beam7.jpg manage 59 K 2010-05-19 - 08:11 StevenWhite  
This topic: KPAF > DirectorsOffice > EngPlanning > PostCommissioning
Topic revision: 2010-05-19, StevenWhite
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.