Regression-style testing of all HBW pulsar modes and all spectral line modes (if time)
Details
Note: Ryan working remotely today
Joe began switching things over shortly after 09:00
First set of scan to test switching signals submitted at 09:45. Will test incoherent and coherent modes just to be safe.
i0100x0512 and i0200x1024 modes properly controlled cal, but i0100x1024 did not
There was abort when trying to go into the first coherent DD mode (c0100x0064)
Ray and Joe did some investigating. They think it was guppi_daq Will try the i0100x1024 mode again and then the coherent modes.
Coherent modes aborted after scan started. Bank D was "hung in aborting".
Joe suggested looking at 200 MHz coherent modes while they diagnose. Submitted SS test scans for c0200 modes only at 10:15
Aborted again after first few seconds of scan
Ryan noted that OBSBW and OBSNCHAN are too small by a factor of 800/requested_bw again (i.e. a factor of 8 or 4, depending on 100 or 200 MHz mode)
It appears that changes made last week have been lost somehow. Ray is recompiling.
Trying coherent modes again at 10:32. First scan in this set is #8
c0100x0064 looks OK now. Cal is on.
Coherent modes all look OK
Moving on to test all HBW modes. Will use dual backend where applicable. First scan is #17
Incoherent HBW modes all seem to check out.
Coherent modes also seem to be behaving as expected.
Testing a fix to config tool so that GUPPI does not inheret stale VEGAS parameters when it is used on its own.
Joe's fix seemed to work. It sounds like it does a ResetConfig any time the 'backend' keyword changes.
I will need to make sure that this does not cause issues for anything else before releasing.
Pausing at 12:00 for lunch and to allow prospero and LO/Rx control computers to be rebooted.
Starting back up at 12:55. Will do TP scans of all spectral line modes using 4 banks. Will configure for L-Band at 1420 MHz, and will inject tone at 1423 MHz. First scan is #49
Frequency labels were off in gbtidl, almost as if it were still configured for S-Band.
Joe is restarting IF manager
New set of scans starts at #56
Still showing same issue but only in modes 1 -- 3. All other modes have correct frequencies. Tone shows up in correct channel reqardless.
Aborted during Mode 23 scan due to "compare error in sig/ref". Resubmitting starting with Mode 22 (scan #79). No issue second time.
Joe checked logs. Apparently this has been happening "a lot" since October. I guess it's not an issue with the LBW modes specifically...
Remaining spectral line scans finished. Other than Modes 1 -- 3 things look OK
Did another GUPPI scan to check config. No issues.
Doing a VEGAS config, AutoPeakFocus, then VEGAS config and scan to check config sequence.
No motion, so obviously no actual corrections, but procedures seemed to run OK.
Randy provided a new n_chan value of 5 to try for the switching signals in the incoherent modes. Giving that a try.
Still not working for i0100x1024
Wrapping up for today. Joe and Ray started switching back to release branch at 14:30
Checkout went OK. Frequencies were correct in this Mode 1 scan.
Conclusions
Switching control looks good in coherent modes. It looks like we still need n_chan values from Randy for some incoherent modes, but at least some of the incoherent modes are controlling switching correctly.
HBW modes all seem to behave as usual (both coherent and incoherent)
Need to understand and fix frequency labeling in spectral line Modes 1 -- 3