Talked to Joe and Ray. Suggested checking INTEGRAT table. It is, indeed, all zeros. Will therefore set the "normalize_data" flag in vegas.conf to "false" to prevent dividing by INTEGRAT
Trying MODE6 again
"NORMALZD" keyword is zero in shmem, so it seems like the config file change was accepted
Scan is #84
No change
Will try MODE7 without normalization
Scan is #85
No change
Going to take two scans in each mode with the Archivist recording filtersnaps just in case we can play around with that data
Scans are number 86 and 87 (MODE7 and MODE6)
Returned vegas.conf to normal. Confirmed that BOF files and normalization flag are being read correctly with the production values.
Session ended at 12:53
Conclusions
Packet flow and balancing looked good with new BOF files, but for some reason the data is coming out nans. Will need to investigate switching signals and try again.