Check KATCP snaps versus Archivist snaps - Ray has already done this
Total power and spectrum ratios ADC / filtersnap / HPC spectra
Identical ratios for varying input power
Using the new noise source, 300MHz highpass filter, amplifier, attenuator and 8-way splitter
Details
Set up in simulator at 1pm
switching_signal_selector is jumpered around (not sure this is necessary)
Set up lbw_gain. From Randy, empirically the digital filter requires a gain of 5.664 to get -20dBFS into each of real and imag separately, for a -20dBFS input.
So, set lbw_gain to 2**16 (unity in BOF) * 2**8 (Ray correction for old config_tool)*5.664
Output power for filtersnap will be -17dBFS, since real and imag powers are summed together.
By inspection, this is what BOF 123 produces! We have sanity...
Mode 4
bank_gain_mode4_cband_nocal
archivist
setValues with 5.664 (Devexplorer not working well in the simulator, can't check but looks correct.)
Nominal -20dBFS input corresponds to attenuator setting of -5dB
Cannot reset scan number
Scan 63 Aborts - BankE taking too long, same with 64, 65 is ok.
Scan 65 nominal -5dB
Scans 66-70, 3,4,5,6,7dB attenuation - Data look fine, but GBTIDL will only plot one polarization?
Mode 1
bank_gain_mode1_cband_nocal
archivist
SetValues is irrelevant
Attenuation of 5 now corresponds to ~ -20.3dB - stay at this value.