TGBT14A_912_73 - Continued Bank discrepancy tests
Setup
Mode 4; tp_nocal
Mode 4; tp (with cal)
Mode 5; (tp_nocal)
Mode 5; tp (with cal)
Setup
Get Ray to copy in latest version of Manager for me, plus mode 4 = BOF 123, mode 5 = BOF 124.
Fix checkBalanceDB script to include Archivist
Mode 4; tp_nocal
receiver is not responding correctly; Dave restarts it, but to no effect
pol1 seems rock steady
pol2 is jumping about a fair amount - and not changing by a constant no of dB per step.
bank_gain_mode4_kfpa (configured for tp_nocal)
balance(-20)
lbw_gain is now 164332592, which is around 2^27.2
set all lbw_gains to 134217728 (2^27)
converter rack is around 16 - 24
checkBalanceDB(0,31,2)
Scans 1 - 16
at 0dB, all saturating. at 10dB, almost all are in range
Mode 4; tp (with cal)
As above, but configured for tp with cal
scans 17-32
Mode 5; (tp_nocal)
balance(-20)
lbw_gain 165512994
reset to 134217728
checkBalanceDB(0,31,2)
Scans 33-48
Mode 5; tp (with cal)
As above, but configured for tp with cal
scans 49-64
Finish at 5:20pm
--
RichardPrestage
- 2015-02-22
E
dit
|
A
ttach
|
P
rint version
|
H
istory
: r2
<
r1
|
B
acklinks
|
V
iew wiki text
|
Edit
w
iki text
|
M
ore topic actions
Topic revision: r2 - 2015-02-23,
RichardPrestage
CICADA
Log In
Register
CICADA Web
Create New Topic
Index
Search
Changes
Notifications
Statistics
Preferences
Webs
ALMA
NAASC
SCIIPT
CDL
CICADA
Ccs
Littlethings
Cville
DSAA
EVLA
FASR
HPC
JVLA
KPAF
Library
Main
Metrics
NGVLA
NM
Computing
Electronics
OSAA
OSX
SRDP
Software
Algorithms
CASA
Splat
System
VLBA
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding NRAO Public Wiki?
Send feedback