TGBT13B_502_47 - Tests of Mode 10 - 19

Goals

  • try and track down Tsys / Intensity issues with Modes 10 - 19

Details

  • X-band, frequency - 9000 MHz
  • Scan 1 TsysMode19Track test scan. Online filler doesn't seem to be filling - do so by hand. Tsys = 16K. Try injecting a test tone
  • Scan 2 TsysMode19Track Test tone 9005 MHz, -50dB
  • Scan 3 TsysMode19Track Test tone 8095 MHz, -50dB
  • Scan 4 TsysMode19Track Test tone 8950 MHz, -50dB
  • Scan 5 TsysMode19Track Test tone 8950 MHz, -90dB - looks good
  • Scan 6 TsysMode19Track SWPER = TINT = 1.0, bary regular Cal switching, Tone
  • Scan 7 TsysMode19Track SWPER = TINIT = 5.0, bary, regular Cal switching, Tone
  • Scan 8 TsysMode19Track SWPER = TINIT = 10.0, bary, regular Cal switching, Tone
  • Use Scan coordinator to flip order of Cal On and Cal Off
  • Scan 9 TsysMode19Track SWPER = TINIT = 10.0, bary, switched Cal, Tone
  • Scan 10 TsysMode19Track SWPER = TINIT = 5.0, bary, switched Cal, Tone
  • Scan 11 TsysMode19Track SWPER = TINIT = 1.0, bary, switched Cal, Tone
  • Scan 12 TsysMode19Track SWPER = TINIT = 1.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 13 TsysMode19Track SWPER = TINIT = 5.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 14 TsysMode19Track SWPER = TINIT = 10.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 15 TsysMode10Track SWPER = TINIT = 1.0, bary, normal CAL, tone
  • Scan 16 TsysMode10Track SWPER = TINIT = 5.0, bary, normal CAL, tone
  • Scan 17 TsysMode10Track SWPER = TINIT = 10.0, bary, normal CAL, tone
  • Scan 18 TsysMode10Track SWPER = TINIT = 10.0, bary, switched CAL, tone
  • Scan 19 TsysMode10Track SWPER = TINIT = 5.0, bary, switched CAL, tone
  • Scan 20 TsysMode10Track SWPER = TINIT = 1.0, bary, switched CAL, tone
  • Scan 21 TsysMode10Track SWPER = TINIT = 1.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 22 TsysMode10Track SWPER = TINIT = 5.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 23 TsysMode10Track SWPER = TINIT = 10.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 24 TsysMode24Track SWPER = TINIT = 1.0, bary, normal CAL, forgot tone
  • Scan 25 TsysMode24Track SWPER = TINIT = 1.0, bary, normal CAL, tone
  • Scan 26 TsysMode24Track SWPER = TINIT = 5.0, bary, normal CAL, tone
  • Scan 27 TsysMode24Track SWPER = TINIT = 10.0, bary, normal CAL, tone
  • Scan 28 TsysMode24Track SWPER = TINIT = 10.0, bary, switched CAL, tone
  • Scan 29 TsysMode24Track SWPER = TINIT = 5.0, bary, switched CAL, tone
  • Scan 30 TsysMode24Track SWPER = TINIT = 1.0, bary, switched CAL, tone
  • Scan 31 TsysMode24Track SWPER = TINIT = 1.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 32 TsysMode24Track SWPER = TINIT = 5.0, bary but tolerance = 1MHz, normal CAL, tone
  • Scan 33 TsysMode24Track SWPER = TINIT = 10.0, bary but tolerance = 1MHz, normal CAL, tone

Analysis

This topic: CICADA > WebHome > GreenBankSpectrometer > CICADAGreenBankSpectrometerCommissioningLogs > CICADAGreenBankSpectrometer2014Mar21
Topic revision: 2015-01-27, RichardPrestage
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding NRAO Public Wiki? Send feedback