VEGAS Testing 2013 August 13

Goals

  • Continued software testing - fix mode 2 and 3 - appears to be successful.

Observing Details

  • Use project code TGBT13B_502 - Session 3
  • Scan 1 LbandMode2Works - runs ok - no switching states
  • Scan 2 LbandMode2DoesntWork - frequency and cal switching - now it works !!!
  • Scan3 LbandMode3SpecStow - doesn't work
  • Scan 4 - repeat with Advanced Sig/Ref disconnected from SS box - still doesn't work.
  • Ray tries to manually set blanking longer in one bank - runs it manually, takes data
  • accidentally close Firefox and loose some of the log file.
  • Ray believes he has a fix
  • Scan 6 LbandMode3SpecStow - now appears to work! fill this data
  • Ray makes some more changes
  • Scan 7 - Bank A aborts...
  • Scan 8 Works
  • Scan 9 - LbandMode2DoesntWork - now works
  • Ray removes all print statements from his code...
  • Scan 10 - LbandMode3SpecStow - works
  • Ray makes one more change
  • Bank A dies with a slew of error messages - Ray restarts it
  • Scan 11 LbandMode3SpecStow - works
  • 4pm finish

This topic: CICADA > WebHome > GreenBankSpectrometer > CICADAGreenBankSpectrometerAug2013TestPlan > CICADAGreenBankSpectrometer2013Aug13
Topic revision: 2013-08-13, RichardPrestage
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding NRAO Public Wiki? Send feedback