Subsystem | Item | Date Added | Link to JIRA | Notes |
---|---|---|---|---|
FEMC |
Update FEMC firmware to latest available release:2011-12-12 - Rev.2.6.0 released |
2011-01-06 |
This upgrade should be performed only before beginning the PAI acceptance testing. |
|
|
|
|
This will be automatically taken care of if the upgrade to the latest firmware release is performed (see first entry) |
|
Bias Module |
Recall of Revision C2, D & D2 Cartridge Bias Modules from the OSF |
2010-04-09 |
|
|
Cryostat [M&C] |
Rev-A Gate Valve Driver (GVD) Boards SN 001 to 023 Recalled |
2010-07-23 |
|
|
FEEC |
FEEC Production Kits: Side Support Bracket NCR |
2010-05-25 |
|
|
FLOOG |
Recall of FLOOG Distributor Backplanes and Boards |
2010-04-27 |
|
|
FEEC |
FE#4-NCR-03(ALMA Cryostat ID Cable Problem of EA FEIC FE#4) |
2010-05-30 |
|
|
FEEC |
Improper Interface b/w Right Front Corner Plate & Solenoid Valve-to-Cryostat M&C Backplane Cable |
2010-08-17 |
|
|
|
|
|
|
|
WCA |
LO3-11, 26, 36, 40, 41, 44, 45, 46 Possible Loose Screws |
2010-09-14 |
|
|
WCA |
WCA Upgrade Watchlist |
2010-09-21 |
This is a dynamic list, check it often. |
|
FE M&C Kits |
Rev-B&C Gate Valve Driver |
2011-01-24 |
|
|
LPR fibers |
Fiber optic cable not adequately secured by fiber optic clamps on WCA faceplates |
2011-02-10 |
|
|
Band 3 CCA |
Band 3 Cartrdige - Update of the temperature sensor offset values |
2011-02-10 |
|
|
FEEC |
FLOOG Cables |
2011-03-01 |
At a minimum Band 8&9 cables should undergo continuity check. |
|
Band 3 CCA |
Output IF Attenuator Update |
2011-04-14 |
|
|
Band 6 CCA |
Band 6 Cartridge - Update of the temperature sensor offset values |
2011-04-21 |
|
|
FEEC |
Remove lock washer from pannel latch |
2011-05-02 |
(Page 182, Fig.213, Step 50) and (Page 189, Fig. 224, step 51) contains the drawing and details. |
|
CPDS |
CPDS Rev. B Backplane Retrofit |
2011-05-24 |
|
|
Cryostat IONIVAC ITR90 transmitters |
Incorporate filtered center ring |
2011-08-30 |
This upgrade to be applied upon receipt of upgrade kits from RAL. |
|
FE M&C Kits |
Rev D Gate Valve Driver Update |
2011-10-28 |
Latest GVD upgrade - required |
|
IF Switches |
Remove and Replace faulty IF switches |
2013-02-08 |
|
|
FEMC |
Update for CART8.INI released. The new version contains the correct value for the SIS current sense resistor and should replace the current version in the FEMC module. |
2012-01-27 |
For update instruction consult the appropriate section of the Front End Operation Manual. |
|
Band 6 CCA |
Remove shrink wrap on magnets. |
2012-02-08 |
Inspect and update all Band 6 CCAs prior to installation |
|
FEMC |
Update for WCA5.INI released. The new version contains the correct selection for the PLL loop bandwidth gain selection and should replace the current version in the FEMC module. |
2012-04-13 |
For update instruction consult the appropriate section of the Front End Operation Manual. |
|
FEMC |
Update for WCA10.INI released. The new version contains the correct selection for the PLL loop bandwidth gain selection and should replace the current version in the FEMC module. |
2012-04-13 |
For update instruction consult the appropriate section of the Front End Operation Manual. |
I | Attachment | Action | Size | Date | Who | Comment |
---|---|---|---|---|---|---|
zip | cart8.zip | manage | 940 bytes | 2012-01-27 - 11:31 | UnknownUser | Update version of cart8.ini configuration file with corrected SIS current sense resistor value. |
zip | wca10.zip | manage | 470 bytes | 2012-04-13 - 13:45 | UnknownUser | Update version of wca10.ini configuration file with corrected PLL loop bandwidth selection. |
zip | wca5.zip | manage | 468 bytes | 2012-04-13 - 13:45 | UnknownUser | Update version of wca5.ini configuration file with corrected PLL loop bandwidth selection. |