Delivered Data

CONFIGURATION AND OPERATING PARAMETERS

cartridge status notes
Band 3 #1 OK See comments on ALMA EDM for specific data format issues.
Band 3 #2 OK  
Band 3 #3 Missing LOParams See additional comments on ALMA EDM.
Band 3 #6 OK  
Band 3 #7 OK  
Band 3 #8 OK  
Band 6 #1 OK Some errors in XML needed inspection & correction.
Band 6 #8 OK  
Band 7 #1 OK Need warm IF plates data.
Band 7 #2 OK  
Band 7 #4 OK  
Band 7 #7 OK  
Band 9 #1 OK Delivered as an MS Access database. Should be plain text or XML.
Band 9 #2 OK Delivered as an MS Access database. Should be plain text or XML.
Band 9 #3 OK Delivered as an MS Access database. Should be plain text or XML.
Band 9 #4 OK Delivered as an MS Access database. Should be plain text or XML.
Band 9 #6 OK Delivered as an MS Access database. Should be plain text or XML.
Band 9 #8 OK Delivered as an MS Access database. Should be plain text or XML.

TEST DATA

Cartridge NOISE IMAGE S.B. INBAND TOTAL POWER GAIN AMPL. PHASE
  TEMP. SUPPR. RATIO POWER POWER VAR. COMP. STAB. DRIFT
Band 3 #1 OK OK N/A OK OK OK OK OK OK
Band 3 #2 OK OK N/A OK OK OK   OK  
Band 3 #3 OK OK N/A OK OK OK OK OK OK
Band 3 #6 OK OK N/A OK OK OK OK OK OK
Band 3 #7 OK OK N/A OK OK OK OK OK OK
Band 3 #8 OK OK N/A OK OK OK OK OK OK
Band 6 #1 OK OK N/A OK OK OK OK OK OK
Band 6 #8     N/A            
Band 7 #1     N/A            
Band 7 #2     N/A            
Band 7 #4     N/A            
Band 7 #7     N/A            
Band 9 #1 OK N/A OK OK OK OK OK OK SEE NOTE
Band 9 #2 OK N/A OK OK OK OK OK OK SEE NOTE
Band 9 #3     N/A            
Band 9 #4     N/A            
Band 9 #6     N/A            
Band 9 #8     N/A            


Cartridge BEAM IF POL. XPOL XPOL I-VSorted ascending
Band 3 #1   OK        
Band 3 #2   OK        
Band 3 #3 SEE NOTE OK   SEE NOTE    
Band 3 #6   OK        
Band 3 #7   OK        
Band 3 #8   OK        
Band 6 #1 INCOMPLETE OK OK      
Band 6 #8            
Band 7 #1            
Band 7 #2            
Band 7 #4            
Band 7 #7            
Band 9 #1 SEE NOTE OK OK INCOMPLETE OK  
Band 9 #2 OK OK OK INCOMPLETE OK  
Band 9 #3            
Band 9 #4            
Band 9 #6            
Band 9 #8            
  PATTERN SPECTRUM ACCURACY PATTERN TOTAL CURVE


NOTES
  • Phase Drift:
    • For Band 9 #1, phase drift data was provided as phase vs. time.
    • For Band 9 #2, phase drift looks closer to what's expected. See the new document linked above for clarifications.
  • Beam Pattern:
    • For Band 3 #3, the beam pattern data gives copol. The Cross-Polarized file gives only XPol power. Does this point to a redundancy in the data format or does it make sense to have both types of data files?
    • For Band 6 #1, the beam pattern data seems to be incomplete. Only roughly 1/4 of the pattern is visible.
    • For Band 9 #1, pattern data was given as normalized between zero and one.
  • Cross-Polarized Beam Pattern:
    • The new document linked above clarifies how XPOL pattern and XPOL total should be provided.



Older links:

  • CartDataSamplesExamples gives sample cartridge data and the transactions which occur when new or updated data is delivered.

  • Following up on the 2005-05-17 teleconference, MorganMcLeod has been working on database designs for the cartridge operating parameters and the cartridge test data. The data in these databases are to be delivered simultaneous with each cartridge to the FEIC.

  • AccessToMySQL gives information and instructions on setting up MySQL and on moving data from MS Access into MySQL.

This topic: ALMA > WebHome > FrontEndIntegrationCenter > CartridgeDataDelivery
Topic revision: 2008-06-13, MorganMcLeod
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.